Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 431: Stratum-3 Clock Alarm Query Test (#649) 3 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2 FAIL One power supply failed. This <strong>error</strong> occurs when the Stratum-3 clock has<br />

two power supplies <strong>and</strong> one of them has failed. However, the clock can<br />

function with one power supply.<br />

1. Locate the failed power supply (the one with a red LED), <strong>and</strong><br />

replace it. The power supplies reside under the Stratum-3 clock’s<br />

carrier.<br />

2. To determine whether the alarm still exists, enter <strong>test</strong> synch r 4<br />

to clear the alarm. If any <strong>test</strong> repetitions fail, follow the procedures<br />

for those failures.<br />

4 FAIL One clock unit failed.<br />

1. Look at the Stratum-3 cabinet for a red LED on a circuit card<br />

marked “ST3.” Replace the card.<br />

2. To determine whether the alarm still exists, enter <strong>test</strong> synch r 4<br />

to clear the alarm. If any <strong>test</strong> repetitions fail, follow the procedures<br />

for those failures.<br />

1438 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />