19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 517: IP Address Update Test (#1371) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

6 FAIL The packet link for the board is not up.<br />

1. Check the state of the packet bus for the port network.<br />

2. If the packet bus is OK, attempt to re-initialize the board by entering<br />

the following comm<strong>and</strong>s:<br />

- disable ip-interface<br />

- reset board location<br />

- release board location<br />

3.<br />

- enable ip-interface.<br />

If the problem persists, replace the circuit pack.<br />

2807 FAIL The board is administered, but not enabled on the change<br />

ip-interfaces form. The board <strong>and</strong> its DSPs are taken out of service.<br />

1. Enable the board on the change ip-interfaces form.<br />

2. Rerun the <strong>test</strong>.<br />

3. If the problem continues, replace the circuit pack.<br />

PASS Translation data matches.<br />

4 PASS Duplicate IP address detected. Circuit pack administration contains an IP<br />

address that is a duplicate of an existing network IP address. This could<br />

cause problems in the network <strong>and</strong> problems with calls on the circuit pack.<br />

Registration Status Inquiry Test (#1372)<br />

The Registration status inquiry reports the H.323 registration status of the endpoint. An endpoint<br />

must be registered <strong>and</strong> authenticated in order to receive service from the system.<br />

Registration is initiated when the endpoint user attempts to login using the <strong>Avaya</strong> registration<br />

software application running on the endpoint PC. The user must provide a valid extension <strong>and</strong><br />

security code. The registration messages are sent to the IP address of a C-LAN Ethernet port.<br />

A registered extension has a port type of SNNNNN, where N is a digit from 0–9. A<br />

non-registered extension has a port type of X.<br />

This <strong>test</strong> runs on DIG-IP-S (Digital IP Station) <strong>and</strong> H323-STN (H.323 IP Station).<br />

1648 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!