Table 334: OLS/Power Unit Query Test (#127) 3 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

FAIL<br />

(cont’d)<br />

Description / Recommendation<br />

4. If the replaced OLS(s) still do not operate properly, then a circuit<br />

pack or a defective telephone connected to a circuit pack in the<br />

affected carrier could be causing an electrical load that is preventing<br />

the OLS from operating properly. Unseat every circuit pack in the<br />

carrier, <strong>and</strong> enter recycle carrier.<br />

a. If the recycle passes, the OLSs are healthy <strong>and</strong> the problem is<br />

with one of the circuit packs. Reinsert the circuit packs one at a<br />

time. If the status LED shows red after reinserting a circuit pack,<br />

replace the defective circuit pack. If the status LED still shows<br />

red, remove the amphenol connector on the back of the slot<br />

containing this circuit pack <strong>and</strong> enter recycle carrier. If the<br />

status LED shows green, the problem is with one of the<br />

telephones or the wiring to one of the telephones on this slot.<br />

b. If either OLS still shows a red status LED, check for bent pins<br />

<strong>and</strong> cable placement in the affected carrier. There are failures<br />

that can occur on the PN’s Maintenance circuit pack that will not<br />

be detected by their respective maintenance, but that will cause<br />

many, if not every, environment <strong>test</strong> to fail. If many environment<br />

<strong>test</strong>s are failing, the suspect circuit pack, depending on the<br />

system configuration, should be replaced <strong>and</strong> the <strong>test</strong> rerun.<br />

1228 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />