Table 350: Analog Looparound Test (#161) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Analog Looparound Test (#161)<br />

1004 ABORT A valid call seized the port during the <strong>test</strong> <strong>and</strong> aborted the <strong>test</strong>.<br />

1. Enter display port location to determine the station<br />

extension.<br />

2. Enter status station extension to determine the service state<br />

of the port.<br />

3. If the port is active, wait until it is idle before <strong>test</strong>ing. Retry the<br />

comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

4. If the <strong>test</strong> continues to abort, escalate the problem.<br />

1005 ABORT The <strong>test</strong> is not applicable for this type of port. This <strong>error</strong> can be ignored.<br />

1018 ABORT The <strong>test</strong> has been disabled by administration. Determine why the Test<br />

field on the change station screen has been set to n for this station. It<br />

may be due to the brief ringing disturbance that Ringing Application Test<br />

48 may cause.<br />

1. To enable the <strong>test</strong> for the particular analog station, enter<br />

change station extension <strong>and</strong> enter y in the Test field.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to abort, escalate the problem.<br />