SNC-LINK (Switch Node Clock Link)<br />

S8700-series Fiber-PNC<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

SNC-LINK MIN <strong>test</strong> board location SNC Link<br />

The SNC-LINK MO reports <strong>error</strong>s in communications between the active Switch Node Clock<br />

<strong>and</strong> Switch Node Interfaces over the serial chel (Aux Data 1) <strong>and</strong> the TPN link (Aux Data 2).<br />

SNC-LINK <strong>error</strong>s are described on the following pages. For a complete description of SNCs <strong>and</strong><br />

SNIs, including circuit pack replacement instructions, see SNI-BD (SNI Circuit Pack) <strong>and</strong><br />

SNC-BD (Switch Node Clock Circuit Pack).<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 233: SNC-LINK Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

SNI<br />

Slot 1<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 0 (a) Any Any Any <strong>test</strong> board location<br />

1 1 (b) 2 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1 2 (c) 2 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

257 1 (b) 3 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

257 2 (c) 3 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

513 1 (b) 4 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

513 2 (c) 4 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

769 1 (b) 5 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

769 2 (c) 5 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1025 1 (b) 6 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1025 2 (c) 6 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1281 1 (b) 7 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1281 2 (c) 7 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

1537 1 (b) 8 Failure audit (#777) MIN OFF <strong>test</strong> board location<br />

854 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 2