POW-SUP (Power Supply)<br />

G650<br />

MO name in<br />

Log<br />

POW-SUP MAJ<br />

MIN<br />

WRN<br />

Alarm level 1<br />

Initial Comm<strong>and</strong> to Run Full name of MO<br />

<strong>test</strong> board location long Power Supply<br />

1. This is a minor alarm if there is a redundant power supply, <strong>and</strong> a major alarm if there is only one power<br />

supply.<br />

The POW-SUP maintenance object notes the presence of each power supply <strong>and</strong> the voltage of<br />

each power supply in the G650.<br />

This MO:<br />

● Verifies that a power supply that is administered is physically present<br />

● Verifies that each output voltage (+5V, -5V, <strong>and</strong> -48V for the power supplies <strong>and</strong> +12V for<br />

the fan) is within tolerance<br />

● Is used with the recycle carrier comm<strong>and</strong> to momentarily turn off <strong>and</strong> on the power to<br />

a specified power supply or to a specified carrier<br />

● Is used to turn off output voltages from one power supply to verify that the other supply can<br />

support the entire load of the G650 (This is used only when a G650 has redundant power<br />

supplies.)<br />

There is one instance of this MO for each 655A power supply equipped in a G650 stack. Refer<br />

to G650 Cabinet Environmental Hardware Components for further information.<br />

If you have redundant power supplies, <strong>and</strong> both are operating, you can unplug one power<br />

supply <strong>and</strong> leave it unplugged for ten minutes without causing an alarm. If the remaining<br />

operating power supply has an alarm, the system does not wait ten minutes to generate an<br />

alarm. It generates an alarm immediately. If the power supply is unplugged for more than ten<br />

minutes, the system generates a warning alarm with an Error Code 23. If you need the power<br />

supply to be unplugged for more than ten minutes, <strong>and</strong> you do not want the system to generate<br />

an alarm, use the change circuit-pack comm<strong>and</strong> to un-administer the power supply.<br />

778 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers