Table 37: Error type 1281 Aux Data <strong>and</strong> repair procedures 3 of 3<br />

Aux<br />

Data<br />

Alarm<br />

Description<br />

23 High-level path<br />

Remote defect<br />

Indicator:<br />

HP_RDI<br />

24 Loss of cell<br />

delineation<br />

(LCD)<br />

27 SIGCON_DO<br />

WN ATM<br />

switch high<br />

level signal<br />

Repair procedure<br />

ATM-EI (Expansion Interface Circuit Pack)<br />

The far end is detecting a major problem with the signal that this<br />

board is transmitting. The transmitted payload is invalid.<br />

1. Make sure the ATM switch port (or a MUX port, if present between<br />

ATM switch <strong>and</strong> the ATM-EI board) is the same as the ATM-EI<br />

circuit pack’s cable interface.<br />

2. Run <strong>test</strong> board location. If the Test #1259 fails with Error<br />

Code 23, connect a fiber back-to-back in a looped mode (one<br />

str<strong>and</strong> of fiber connecting the transmit transceiver to the receive<br />

transceiver of the board) <strong>and</strong> see if the amber LED flash goes<br />

away.<br />

3. If it does, the problem is off-board.<br />

4. If the amber LED continues to flash, replace the circuit pack.<br />

On board ATM framer chip is not able to frame cells based on the<br />

cell header.<br />

1. Reset the board (reset board location).<br />

2. If the <strong>error</strong> persists, replace the board.<br />

The board cot communicate with the ATM switch.<br />

1. Busyout the board with busyout board location.<br />

2. Test the board with <strong>test</strong> board long location.<br />

3. Release the board with release board long location.<br />

4. If Test #1260 fails, replace the board.<br />

5. If Test #1260 passes, make sure the ATM address on both the<br />

server <strong>and</strong> the ATM switch sides are the same for this board.<br />

6. If the address is the same, change the port on the ATM switch<br />

side. This could require administration on the ATM switch.<br />

7. If the <strong>error</strong> is resolved, the problem is on the ATM switch port.<br />

m. Error Type 1537: LAN bus time out. The circuit pack is transmitting a packet larger than<br />

1,024 bytes. Replace the circuit pack.<br />

n. Error Type 1538: A hyperactive ATM-EI circuit pack is generating an excessive amount of<br />

control messages to the processor. When this <strong>error</strong> is generated, the system automatically<br />

resets the ATM-EI.<br />

Duplicated PNC? Then:<br />

Yes service to the PN is disrupted<br />

No the system switches to the st<strong>and</strong>by PNC<br />

3 of 3<br />

Issue 5 May 2009 139