To Enable PNC Duplication<br />

To enable PNC duplication:<br />

1. Enable PNC-DUP on the change system-parameters customer-options screen.<br />

2. Fully administer duplicate fiber link connectivity. Verify by entering list fiber-link.<br />

For IP Duplication go to Step 3.<br />

3. Fully administer IPSI duplication (ipserver-interface duplication). Verify by<br />

using list ipserver-interface.<br />

4. Turn on PNC-DUP using the change system-parameters duplication screen.<br />

This is not allowed if any component of either PNC (A or B) is busied out.<br />

5. The system must insert all connectivity-related components for both st<strong>and</strong>by <strong>and</strong> active<br />

PNC. For CSS configurations this takes up to 5 minutes depending upon CSS circuit pack<br />

insertion. For Direct Connect configurations this is declared complete at 5 minutes after<br />

the first appearance of the terminal login prompt.<br />

6. The PNC-DUP initialization anti-thrashing timer must expire (this occurs 5 minutes after<br />

completion of board insertion, PNC interchange, or system reset of level 2 or higher).<br />

To Disable PNC Duplication<br />

To disable PNC duplication perform the following sequence of steps:<br />

1. Verify that the A-PNC is active. A forced interchange may be required. See reset pnc in<br />

Chapter 8.<br />

2. Busyout the st<strong>and</strong>by PNC (B-PNC).<br />

3. Turn off the system parameter for PNC-DUP using change system-parameters<br />

duplication.<br />

After PNC duplication has been removed, configuration audits generate the alarm shown<br />

below <strong>and</strong> possibly others. To clear this alarm, the B-PNC fibers, circuit packs in switch<br />

node carriers (EIs, SNIs, SNCs, <strong>and</strong> DS1Cs), <strong>and</strong> switch node carriers must be removed<br />

as outlined in the following steps.<br />

01D SN_CONF 5000 255<br />

In this case, 01D is the B-PNC switch node from which duplication was removed.<br />

758 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers