Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

● XXX-BD (Common Port Circuit Pack/Media Module).<br />

Table 303: Ringing Application Test (#51) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system <strong>error</strong>. Could not allocate the necessary system resources<br />

to run <strong>test</strong>. The circuit pack is not installed.<br />

1000 ABORT System resources required to run <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the <strong>test</strong>.d.<br />

1. Enter display port location to determine the station<br />

extension. Enter status station to determine the service state of<br />

the port. If the service state indicates that the port is in use, wait until<br />

the port is idle before re<strong>test</strong>ing.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1008 ABORT Could not allocate a ringing circuit for one of the following reasons: all the<br />

ringing circuits are in use; the ringing generator is defective; ringing<br />

generator is not wired correctly.<br />

1. If the <strong>test</strong> continues to abort, look for RING-GEN <strong>error</strong>s in the Error<br />

Log.<br />

a. If there are RING-GEN <strong>error</strong>s, see RING-GEN (Analog Ring<br />

Generator) <strong>and</strong> try to resolve any problem(s). Then retry the <strong>test</strong><br />

at 1-minute intervals up to 5 times.<br />

b. If there are no RING-GEN <strong>error</strong>s, <strong>and</strong> the <strong>test</strong> continues to abort,<br />

enter <strong>test</strong> board location on other TN742, TN769, or<br />

TN746 Analog circuit packs. If an ABORT with Error Code 1008<br />

occurs for this <strong>test</strong> on other circuit packs as well, then the ringing<br />

generator may be defective or may not be wired properly. See<br />

RING-GEN (Analog Ring Generator) maintenance<br />

documentation for details. If an ABORT with Error Code 1008<br />

does NOT occur on the other ports, then all four ring generators<br />

are in use. No further action is necessary.<br />

2. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1412 ABORT This <strong>test</strong> does not run on media modules or media gateways. Ignore.<br />

1156 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

1 of 2