DIG-LINE (Digital Line)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

DIG-LINE MIN <strong>test</strong> port location long Digital Line<br />

DIG-LINE maintenance monitors <strong>and</strong> <strong>test</strong>s ports on digital line circuit packs or digital line media<br />

modules <strong>and</strong> on hardware administered as a digital station on those ports. These include<br />

stations with only a digital phone <strong>and</strong> stations with a digital phone linked to a data module.<br />

St<strong>and</strong>alone data modules <strong>and</strong> data adaptors in st<strong>and</strong>alone mode are covered by PDMODULE<br />

(Processor Data Module).<br />

Circuit pack maintenance is covered by DIG-BD (Digital Line Circuit Pack), the strategy for<br />

which is described in XXX-BD (Common Port Circuit Pack/Media Module).<br />

The following circuit packs support digital lines:<br />

Table 84: Digital Line Circuit Packs<br />

WRN <strong>test</strong> port location<br />

Code Ports Type Comp<strong>and</strong>ing Endpoints<br />

TN754<br />

TN754B<br />

TN2181<br />

TN2224B/CP<br />

TN2136<br />

TN2181<br />

TN2224B/CP<br />

8<br />

8<br />

16<br />

24<br />

8<br />

16<br />

24<br />

4-wire DCP<br />

4-wire DCP<br />

2-wire IDCP<br />

2-wire IDCP<br />

2-wire IDCP<br />

2-wire IDCP<br />

2-wire IDCP<br />

mu-law<br />

A-law/mu-law<br />

A-law/mu-law<br />

A-law/mu-law<br />

A-law/mu-law<br />

A-law/mu-law<br />

A-law/mu-law<br />

Each digital line port supports two 64 kbps information chels (primary <strong>and</strong> secondary) <strong>and</strong> one<br />

8kbps signaling chel. Digital voice terminals always use the primary information chel, <strong>and</strong> only<br />

one voice terminal can be connected to each port. The secondary information chel can be used<br />

to connect a data terminal via a Digital Terminal Data Module (DTDM) or a Data Adaptor (DA).<br />

All other devices currently supported by Digital Line circuit packs communicate on the primary<br />

information chel. Figure 14: Digital Line Connectivity shows examples of digital line<br />

connectivity.<br />

Use only the TN754B or TN2136 circuit packs in out-of-building applications.<br />

The TN2181 <strong>and</strong> TN2224B/CP support both modes as shown in Figure 14: Digital Line<br />

Connectivity <strong>and</strong> Figure 15: Digital Line Connections.<br />

318 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

7400 series digital voice<br />

terminals, attendant consoles,<br />

510D personal terminals,<br />

MT515 BCTs, DCP data<br />

modules<br />

Data Adaptors (DA), Italtel<br />

Digital Telephone Models 1 <strong>and</strong><br />

2 (IDT1/2).