Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 293: Port Diagnostic Test (#35) 4 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1392 ABORT This port is a TTI port. The <strong>test</strong> will not run on TTI ports.<br />

1. Verify that the port is a TTI port using either display port,<br />

which shows that the port is a TTI port, or list config, which<br />

shows a t for the port.<br />

2. If either comm<strong>and</strong> indicates that the port is a TTI port, the abort is<br />

correct for the <strong>test</strong> <strong>and</strong> no action is necessary.<br />

3. If the port is not a TTI port, escalate the problem.<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2012 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2100 Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

61446 FAIL DID-TRK: Battery feed <strong>test</strong> failed. A loop current fault was detected.<br />

This is most likely an incoming CO-line problem.<br />

1. Check the incoming CO-line for loop current. If none is detected<br />

refer the problem to the CO.<br />

2. If the CO-line checks out OK, the failure must be on the DID port.<br />

Replace the circuit pack.<br />

61456 FAIL DID-TRK: Battery feed <strong>test</strong> failed. An on-board problem was detected.<br />

This port is out-of-service.<br />

1. Replace the circuit pack or media module.<br />

61472 FAIL DID-TRK: Battery feed <strong>test</strong> failed. A problem with the incoming CO-line<br />

was detected.<br />

1. Check the incoming CO-line for proper operation. If warranted,<br />

refer the problem to the CO.<br />

2. If the CO-line is not at fault, the failure must be on the DID port.<br />

Replace the circuit pack or media module.<br />