Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Clear Error Counters Test (#270)<br />

This <strong>test</strong> is not an actual <strong>test</strong> in the strict sense of the word. Many circuit packs have counters in<br />

the Angel firmware. These counters are used so that Control Chel Message Set (CCMS)<br />

messages are not continuously sent uplink to maintenance software. Using this method, the<br />

message will be sent until the counter reaches some preset threshold, then not sent again until<br />

the counter is cleared.<br />

The ports on the circuit pack continually run self-<strong>test</strong>s whenever the port is idle. This <strong>test</strong> clears<br />

the counter so that if the port continues to fail during or after <strong>test</strong>ing, the Angel will send a<br />

message to indicate that fact.<br />

This <strong>test</strong> is only used to send a downlink message to the Angel on the circuit pack. Since the<br />

Angel normally provides no uplink response to this message, this <strong>test</strong> should never abort or fail.<br />

This <strong>test</strong> is run on the following maintenance objects:<br />

● ASAI-PT (ASAI Port)<br />

● BRI-PORT (ISDN-BRI Port)<br />

● M/T-ANL (Maintenance/Test Analog Port)<br />

● M/T-DIG (Maintenance/Test Digital Port)<br />

● M/T-PKT (Maintenance/Test Packet Bus Port)<br />

● TBRI-PT (ISDN Trunk-Side BRI Port)<br />

Table 383: Clear Error Counters Test (#270)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Any ABORT This <strong>test</strong> should never abort.<br />

Any FAIL This <strong>test</strong> should never fail.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to fail, escalate the problem.<br />

PASS The message to clear the circuit pack’s counter for Background<br />

Maintenance Failures has been sent successfully.<br />

1342 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers