Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 540: Serial Bus Status Test (#1531) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

FAIL<br />

(cont’d)<br />

Description <strong>and</strong> recommendation<br />

Procedure 2: This procedure attempts to isolate the Serial Bus failure to<br />

a particular set of carriers. Only the circuit packs in selected carriers are<br />

checked. Procedure 2 is organized into two parts. Part 1 attempts to<br />

clear the Serial Bus fault by replacing all the bus cabling <strong>and</strong> terminators<br />

within a port-network. Part 2 attempts to isolate the fault to a particular<br />

carrier by extending the Serial Bus from the A carrier to additional<br />

carriers one at a time.<br />

WARNING: Power must be removed from the entire port network<br />

before any cables or terminators are removed. Failure to<br />

follow this procedure can cause damage to circuit packs<br />

<strong>and</strong> power supplies, <strong>and</strong> can be hazardous to the<br />

technician.<br />

Part 1:<br />

1. If spare TDM/LAN Cable assemblies <strong>and</strong> TDM/LAN Bus<br />

Terminators are not available, go to Part 2 of this procedure.<br />

2. Power down the port network.<br />

3. Replace all of the TDM/LAN Cable Assemblies <strong>and</strong> both TDM/<br />

LAN Bus Terminators.<br />

4. Restore power to the port network.<br />

5. Run list configuration power-supply C to determine if<br />

the Serial Bus fault is still present.<br />

6. If the Serial Bus fault is resolved, the procedure is completed.<br />

Otherwise, go to Part 2.<br />

Part 2:<br />

1. Terminate the TDM/LAN Bus so that it extends only across the<br />

carrier that contains the A carrier TN2312BP IPSI.<br />

2. Determine if the Serial Bus fault is still present by running list<br />

configuration power-supply C.<br />

1686 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />