TN464 circuit packs support the following:<br />

● Digital Tie, CO, <strong>and</strong> DID trunks<br />

● DS1 off-premises (OPS) lines<br />

● Narrowb<strong>and</strong> <strong>and</strong> wideb<strong>and</strong> access endpoint ports<br />

● ISDN-PRI trunks <strong>and</strong> accompanying signaling chel<br />

● PRI endpoint ports (PE-BCHL) <strong>and</strong> accompanying signaling chel<br />

The TN464 supports digital Tie, CO, <strong>and</strong> DID trunks, <strong>and</strong> OPS lines. On-board firmware<br />

performs call control signaling for the Tie, CO <strong>and</strong> DID trunks <strong>and</strong> OPS lines. ISDN-PRI trunk<br />

<strong>and</strong> PRI-endpoint signaling (Q.921, Q.931) is received <strong>and</strong> generated by system software <strong>and</strong><br />

is transmitted on a system link through the TN1655 Packet Interface <strong>and</strong> packet bus to the<br />

UDS1 where it is placed on the D chel. Signaling over the DS1 link has to be synchronized<br />

between the transmitting <strong>and</strong> receiving ends to ensure <strong>error</strong>-free communication. See SYNC<br />

(Port Network Synchronization) for details.<br />

Each trunk, line, or endpoint has its own maintenance strategy, but all depend on the health of<br />

the UDS1 Interface circuit pack. See the following Maintenance Objects for details:<br />

TIE-DS1 (DS1 Tie Trunk)<br />

CO-DS1 (DS1 CO Trunk)<br />

DID-DS1 (Direct Inward Dial Trunk)<br />

OPS-LINE (DS1 Off-Premises Station Line)<br />

ISDN-TRK (DS1 ISDN Trunk)<br />

ISDN-PLK (ISDN-PRI Signaling Link Port)<br />

ISDN-SGR (ISDN-PRI Signaling Group),<br />

WAE-PORT (Wideb<strong>and</strong> Access Endpoint Port)<br />

_PE (Processor Ethernet) Alarms.<br />

Circuit Pack Administration <strong>and</strong> Options<br />

The DS1 configuration for each circuit pack is administered on the DS1 Circuit Pack screen. Bit<br />

Rate is set to 1.544 Mbps for 24-chel systems, <strong>and</strong> 2.048 Mbps for 32-chel systems. Country<br />

Protocol is used to drive layer-3 protocol decisions based on PRI specifications for a given<br />

country (not those related to specific features). Different UDS1 circuit packs may be<br />

administered with different Country Protocols, allowing the switch to act as a gateway between<br />

two incompatible ISDN-PRI implementations (for example, between two different countries). US<br />

systems use country protocol 1.<br />

Set Near-End CSU Type to other for no CSU installed or for an external CSU such as an ESF<br />

T1 CSU, or set to integrated for the 120A1 CSU module or the 401A T1 sync splitter. Setting<br />

the field to integrated causes additional fields to appear for administering the Enhanced<br />

Integrated CSU module. Set E1 Sync-Splitter to y if a 402A or 403A E1 sync splitter is used to<br />

provide timing to an ATM switch. Set Echo Cancellation to y if the echo cancellation<br />

right-to-use feature is enabled <strong>and</strong> the TN464GP/TN2464BP or higher suffix board is to supply<br />

echo cancellation.<br />

1026 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers