Battery <strong>and</strong> Power Supply Query Test (#5)<br />

Battery <strong>and</strong> Power Supply Query Test (#5)<br />

The Battery <strong>and</strong> Power Supply Query Test queries the PN’s Maintenance circuit pack for the<br />

status of the battery pack <strong>and</strong> battery charger, then reports the result. In a DC-powered system,<br />

this <strong>test</strong> should never fail. On AC-powered systems, the <strong>test</strong> turns the battery charger status<br />

LED on <strong>and</strong> off to determine if the battery charger is connected.<br />

Depending on the cabinet type, this <strong>test</strong> runs on the following maintenance objects:<br />

● AC-POWER<br />

● CABINET (Cabinet Sensors)<br />

● CARR-POW (Carrier Power Supply)<br />

● DC-POWER (Single-Carrier Cabinet Environment)<br />

● EMG-XFER (Emergency Transfer)<br />

● EXT-DEV (External Device Alarm)<br />

● POWER<br />

● RMC-ENV (Power/Fan Sensors)<br />

● SER-BUS (Serial Communication Bus)<br />

Table 284: Battery <strong>and</strong> Power Supply Query Test (#5) 1 of 7<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 of 7<br />

Issue 5 May 2009 1077