Table 67: CAB-TEMP Error Log Entries 2 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

513 (c) Power supply<br />

temperature <strong>test</strong> (#1538)<br />

769 (d) Power supply fan <strong>test</strong><br />

(#1538)<br />

On/Off<br />

Board<br />

Notes<br />

a. Error Type 1: the inlet temperature is over the threshold—120 o Fahrenheit (49 o Celsius).<br />

Run <strong>test</strong> board <strong>and</strong> check the results of the Power Supply Temperature Test (#1537).<br />

b. Error Type 257: the exhaust temperature is over the threshold—120o Fahrenheit (49o Celsius). Run <strong>test</strong> board <strong>and</strong> check the results of the Power Supply Temperature Test<br />

(#1537).<br />

c. Error Type 513: the hot spot temperature is over the threshold. Run <strong>test</strong> board <strong>and</strong><br />

check the results of the Power Supply Temperature Test (#1537).<br />

d. Error Type 769: the fan alarm is active. Run <strong>test</strong> board <strong>and</strong> check results of the Power<br />

Supply Temperature Test (#1537).<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

MIN ON <strong>test</strong> enviroment location<br />

1<br />

MAJ <strong>test</strong> board location<br />

MIN ON <strong>test</strong> enviroment location<br />

<strong>test</strong> board location<br />

1. This is a minor alarm if there is a redundant power supply, <strong>and</strong> a major alarm if there is only one power<br />

supply.<br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of investigation Short <strong>test</strong><br />

sequence<br />

Recommended Action<br />

Long <strong>test</strong><br />

sequence<br />

244 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

D/ND<br />

Power Supply Temperature Test (#1537) X X Nondestructive<br />

Power Supply Fan Test (#1538) X X Nondestructive<br />