Communication Manager Maintenance Object Repair Procedures<br />

the AESVCS Link. Failure to receive a response to a heartbeat message results in the<br />

deletion of the AESVCS Link by Communication Manager. Both an AESVCS Session Level<br />

<strong>and</strong> Link level <strong>error</strong> are generated against this condition. Escalate if the <strong>error</strong> persists.<br />

c. Error type 1537 is a log only <strong>error</strong> <strong>and</strong> displayed when an AESVCS Link is deleted from an<br />

AESVCS Session for reasons other than a heartbeat failure. Both an AESVCS Session<br />

Level <strong>and</strong> Link level <strong>error</strong> are generated against this condition. The Aux Data field contains<br />

the reason code.<br />

Aux Data Description<br />

1 The far end closed the socket connection. Check the <strong>error</strong> logs on<br />

the AEVCS Server for more information.<br />

100 The reset aecvcs-link comm<strong>and</strong> was used to close the socket<br />

connection<br />

101 The AESVCS Interface on the IP Services form was disabled.<br />

102 The AESVCS Interface was removed from the IP Services form.<br />

103 The AE Services Server was disabled on the AE Services<br />

Administration page of the IP Services form.<br />

104 The AE Services Server was deleted on the AE Services<br />

Administration page of the IP Services form.<br />

200 The socket connection closed due to an internal <strong>error</strong>. Escalate if the<br />

problem persists.<br />

201 The socket connection was unexpectedly closed by Communication<br />

Manager. Escalate if the problem persists.<br />

202 Communication Manager detected an <strong>error</strong> <strong>and</strong> closed the socket<br />

connection. Escalate if the problem persists.<br />

203 Communication Manager detected an <strong>error</strong> reading from the socket<br />

<strong>and</strong> closed the connection. Escalate if the problem persists.<br />

204 Communication Manager failed to write a complete message <strong>and</strong><br />

closed the socket connection. Escalate if the problem persists.<br />

205 AE Server established a new connection causing Communication<br />

Manager to close the existing one. Escalate if the problem persists.<br />

206 Communication Manager failed to send a heartbeat request <strong>and</strong><br />

closed the socket connection. Escalate if the problem persists.<br />

207 Communication Manager detected a protocol violation <strong>and</strong> closed<br />

the socket connection. Escalate if the problem persists.<br />

68 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />