Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> runs on the SNC-BD (Switch Node Clock Circuit Pack) maintenance object.<br />

Table 448: Switch Node Clock Reset Test (#780) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2300 ABORT The downlink message necessary to run this <strong>test</strong> could not be sent.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2301 ABORT The software timer could not be set for sending the downlink message.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2302 ABORT Software received unexpected message data from the SNC circuit pack.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2303 ABORT The SNC circuit pack responded that the <strong>test</strong> requested is not valid.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2304 ABORT SNC circuit pack responded that it is not able to run the <strong>test</strong> requested by<br />

software.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1498 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />