AC Power Query Test (#78)<br />

AC Power Query Test (#78)<br />

The AC Power Query Test queries either the server’s watchdog via an Ethernet or USB<br />

interface or an MCC PN’s Maintenance circuit pack for the status of the cabinet’s AC power.<br />

The AC Power Query Test (#78) is not valid for DC-powered cabinets <strong>and</strong> should either abort or<br />

pass.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● AC-POWER<br />

● CABINET (Cabinet Sensors)<br />

● CARR-POW (Carrier Power Supply)<br />

● EMG-XFER (Emergency Transfer)<br />

● POWER<br />

Table 316: AC Power Query Test (#78) 1 of 3<br />

Error Code Test<br />

Result<br />

Description / Recommendation<br />

1000 ABORT System resources required to run <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2000 ABORT Response from the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

2. If the <strong>test</strong> continues to ABORT with Error Code 2000, check<br />

for system powering problems with the PN’s A carrier.<br />

Resolve every AC-POWER, CARR-POW, <strong>and</strong> RMC-ENV<br />

alarm. Repeat the <strong>test</strong>.<br />

3. If the <strong>test</strong> still ABORTs with Error Code 2000, check for <strong>and</strong><br />

resolve every MAINT (Maintenance circuit pack) <strong>error</strong> in a PN.<br />

Repeat the <strong>test</strong>.<br />

4. If the <strong>test</strong> still ABORTs with Error Code 2000, escalate the<br />

problem.<br />

2028<br />

2319<br />

2320<br />

2500<br />

ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

1 of 3<br />