Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 431: Stratum-3 Clock Alarm Query Test (#649) 5 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

16 FAIL Every power supply failed.<br />

1. Replace the failed power supplies.<br />

2. If battery backup for the Stratum-3 clock is not supplied or if the<br />

battery backup holdover time has been exceeded, the system will<br />

be referencing the local oscillator on the active TN780 Tone-Clock<br />

circuit pack until software detects that one or both power supplies<br />

have been restored (approximately 40 minutes). To speed up this<br />

restoration, enter <strong>test</strong> synch r 4.<br />

3. Every <strong>test</strong> should pass. If any repetitions fail, follow the procedures<br />

for those failures.<br />

Note: The battery backup resides under the Stratum-3 clock’s<br />

carrier.<br />

32 FAIL Every clock unit failed.<br />

1. Look at the Stratum-3 cabinet for red LEDs on circuit cards marked<br />

“ST3.” Replace the card(s).<br />

2. To determine whether the alarm still exists, enter <strong>test</strong> synch r 4<br />

to clear the alarm.<br />

3. If any <strong>test</strong> repetitions fail, follow the procedures for those failures.<br />

2101 FAIL The TN780 Tone-Clock circuit pack detects loss of signal. See note (h) of<br />

the STRAT-3 Error Log Entries table in the STRAT-3 (Stratum-3 Clock)<br />

documentation for replacement procedures.<br />

PASS The Stratum-3 clock has reported that it has no alarm conditions. If<br />

synchronization problems have been reported, look for SYNC <strong>error</strong>s <strong>and</strong><br />

see SYNC (Port Network Synchronization) for recommended strategy for<br />

the recommended repair procedures for those <strong>error</strong>s.<br />

1440 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />