Table 255: TBRI-PT Error Log Entries 2 of 2<br />

Error<br />

Type<br />

3841 -<br />

3942 (y)<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

See Aux Data Values for Error<br />

3841–3942<br />

On/Off<br />

Board<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: loss of continuity of Layer 1 to the far end. It is assumed that Layer 1 remains<br />

active, even when both B-Chels are idle.<br />

This <strong>test</strong> determines whether Layer 1 is active or not. If Layer 1 is not active, the <strong>test</strong><br />

attempts to activate it. If Layer 1 cot be activated, the port is taken out of service, <strong>and</strong> the<br />

<strong>test</strong> fails.<br />

c. Error Type 129: the far-end switch changed the ISDN service state. The trunk is out of<br />

service on the far end. This may be a temporary condition.<br />

d. Error Type 257: the D-chel failed at Layer 2. Expiration of this timer indicates that attempts<br />

to bring the failed link back into service have not succeeded <strong>and</strong> some recovery actions<br />

should be taken on the associated B-Chels. Upon expiration, associated in-service B-Chels<br />

are put in the out-of-service/far-end state. The timer is cleared when layer 2 is<br />

re-established.<br />

e. Error Type 513: on-board hardware failure. The FIFO RAM buffers have overflowed,<br />

indicating a hardware problem. The circuit pack is having problems transmitting data to the<br />

packet bus.<br />

f. Error Type 514: transmit FIFO Overflow - This <strong>error</strong> indicates that the circuit pack is having<br />

problems transmitting data to the TDM D-chel. This <strong>error</strong> only occurs on a system that<br />

switches the packet implementation of the D-chel over the TDM bus. This <strong>error</strong> indicates an<br />

on-board problem related to the packet implementation of the D-chel.<br />

g. Error Type 769: the port is generating too many uplinks. The link is being suspended. If too<br />

many hyperactive events occur with a certain time, the port is alarmed <strong>and</strong> taken out of<br />

service.<br />

h. Error Type 1025: an expired timer has created an unexpected event. The timer could be<br />

any of the following:<br />

Timer Event<br />

T3031 ISDN T3031 timeout<br />

T3032 ISDN T3032 timeout<br />

944 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Recommended Action<br />