MG_ANN (Media Gateway Announcement Module)<br />

Error log entries<br />

Table 181: MG–ANN Errorr Log Entries<br />

MG_ANN (Media Gateway Announcement Module)<br />

MO Name in Log Alarm Level Initial Comm<strong>and</strong> to Run Full Name of MO<br />

MG-ANN MIN <strong>test</strong> board Media Gateway<br />

Announcement<br />

MG-ANN WRN <strong>test</strong> board Media Gateway<br />

Announcement<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Test to Clear Value<br />

18 0 Busyout board WRN ON release board<br />

257 Any Test # 52 MIN ON <strong>test</strong> board<br />

2561 (a) Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2562 (b) Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2564 (c) Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2563 Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2565 Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2566 Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2567 (d) Any Test # 1683 MIN OFF <strong>test</strong> board<br />

2592 (e) Any MIN OFF<br />

Notes:<br />

a. Error Type 18: the media module has been busied out. Release the media module using<br />

release board location.<br />

b. Error Type 257: transient communication problems between the switch <strong>and</strong> this circuit pack<br />

or media module. Execute <strong>test</strong> board location <strong>and</strong> refer to the repair procedures for the<br />

Control Channel Looparound Test (#52).<br />

c. Error Type 2561: during the last attempted License File audit, the license server did not<br />

respond in time.<br />

d. Error Type 2562: retry Failure <strong>error</strong>. This <strong>error</strong> is only logged. It is not a hardware failure<br />

<strong>and</strong> hence does not start any <strong>test</strong>ing or generate any alarms. This <strong>error</strong> comes from call<br />

processing <strong>and</strong> is generated when a second attempt (retry) to seize an outgoing trunk fails.<br />