Far-End Lightwave Transceiver Loopback Test (#789)<br />

This <strong>test</strong> starts at the specified DS1 converter circuit pack location <strong>and</strong> loops at the Fiber Optic<br />

Terminator (lightwave transceiver) that is connected to the DS1 converter circuit pack at the<br />

other end of the DS1 converter complex. See Figure 108: Far-End Lightwave Transceiver<br />

Loopback Test.<br />

The <strong>test</strong> sends digital data through every DS1 facility chel. Two different <strong>test</strong> patterns are used,<br />

these are hexadecimal values 55 <strong>and</strong> AA.<br />

For a st<strong>and</strong>ard-, duplex-, or high-reliability system (no PNC duplication), this <strong>test</strong> can only be<br />

executed at the endpoint that is closer to the server relative to the neighbor DS1 converter<br />

circuit pack because of its impact on the system control links. The completion of the <strong>test</strong> will be<br />

delayed in this configuration to wait for the recovery of the system control links. For a<br />

critical-reliability system (PNC duplication), the <strong>test</strong> can be executed on any DS1 converter<br />

circuit pack. This <strong>test</strong> runs on the DS1C-BD (DS1 Converter Circuit Pack) maintenance object.<br />

Figure 108: Far-End Lightwave Transceiver Loopback Test<br />

Table 451: Far-End Lightwave Transceiver Loopback Test #789 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Metallic or Fiber Connection<br />

DS1CONV<br />

EI Network<br />

A<br />

Test starts here<br />

DS1CONV<br />

B<br />

Description / Recommendation<br />

Loops here<br />

lightwave<br />

transceiver<br />

Fiber Connection<br />

1410 ABORT No lightwave transceiver is present. The neighbor DS1 converter circuit<br />

pack <strong>and</strong> the fiber endpoint are connected via metallic cable. This <strong>error</strong><br />

may be ignored.<br />

2000 ABORT Test timed out while waiting for a response from the circuit pack<br />

1. .Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />