Note: Make<br />

3. Using a fiber jumper cable, interconnect the transmit <strong>and</strong> receive jacks of the lightwave<br />

transceiver as shown in Figure 30: Interconnection of Lightwave Transceiver Transmit/<br />

Receive Jacks.<br />

Note:<br />

sure that the total length of the fiber jumper cable does not exceed the<br />

maximum length recommended for the fiber link connections between cabinets.<br />

Using cable lengths not within connectivity guidelines can adversely affect <strong>test</strong><br />

results.<br />

4. Go to the front of the cabinet <strong>and</strong> inspect the amber LED.<br />

● If the amber LED flashes on at a rate of once per second, the (EI or SNI) circuit pack or<br />

transceiver should be replaced.<br />

● If the amber LED flashes on at a rate of five times per second, the circuit pack (EI or<br />

SNI) or the lightwave transceiver may need replacement. This condition may also be<br />

due to a faulty system clock on the network containing this EI circuit pack.<br />

● If the amber LED is not blinking, this circuit pack (EI or SNI) <strong>and</strong> the lightwave<br />

transceiver are functioning properly.<br />

5. Replace faulty components <strong>and</strong> reconnect the original fiber. Be sure to reconnect the<br />

fibers properly as noted in step 3. If there is a problem with the PN after re-connecting the<br />

fiber, <strong>and</strong> the PN is connected to a Center Stage Switch, run the Configuration Audit via<br />

<strong>test</strong> board on the SNI circuit pack to which the intervening fiber is connected. See the<br />

SNI-BD section for instructions on interpreting results.<br />

6. Release EI circuit pack or SNI circuit pack with release board location.<br />

442 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers