Modem Pool Audit Test (#99)<br />

Modem Pool Audit Test (#99)<br />

This audit updates the Modem Pool conversion resource status contained in the TN758 Pooled<br />

Modem circuit pack’s microprocessor. It does not <strong>test</strong> the Pooled Modem circuit pack, so there<br />

are no FAIL <strong>codes</strong>. The audit can only be performed on idle conversion resources. If the<br />

conversion resource is in use, the audit aborts.<br />

This <strong>test</strong> runs on MODEM-PT (Modem Pool Port).<br />

Table 322: Modem Pool Audit Test (#99)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Any ABORT The system was not able to allocate all necessary resources to run this<br />

<strong>test</strong>. The conversion resource was in use when the audit was performed.<br />

No repair action is necessary unless the conversion resource was known<br />

to be idle during the <strong>test</strong> (amber in-use LED was off) or was busied out<br />

before the <strong>test</strong> was run. In that case, a TN758 failure condition may exist<br />

<strong>and</strong> the following steps should be used:<br />

1. Busyout both of the TN758 Pooled Modem conversion resources on<br />

the circuit pack containing the failing conversion resource.<br />

2. If the <strong>test</strong> continues to abort, replace the Pooled Modem circuit pack<br />

<strong>and</strong> re<strong>test</strong>.<br />

PASS The audit passed.<br />

Issue 5 May 2009 1201

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!