o. Error Type 2305: reorder message. The trunk could not be seized. This <strong>error</strong> causes the<br />

Tie Trunk Seizure <strong>test</strong> (#73) to run <strong>and</strong> is considered a problem only if that <strong>test</strong> fails, logging<br />

<strong>error</strong> 1793. In this case, the trunk may be placed in the ready-for-service state, allowing only<br />

incoming calls. This service state shows up as disconnected on the Trunk Status screen.<br />

Run the Tie Trunk Seizure Test (#73), <strong>and</strong> follow recommended procedures.<br />

TN439 logs Aux Data 57424 or 50944. Other circuit packs log 50944. This <strong>error</strong> is<br />

associated with Tie Trunk Dial Test (#747) for TN439, Tie Trunk Seizure Test (#73) for<br />

TN497, <strong>and</strong> no <strong>test</strong> for the others.<br />

p. Error Type 2561, 2817: these <strong>error</strong>s apply only to TN497.<br />

q. Error Type 2562: retry failure <strong>error</strong>. This <strong>error</strong> is logged only. It is not a hardware failure <strong>and</strong><br />

hence does not start any <strong>test</strong>ing or generate any alarms. This <strong>error</strong> comes from call<br />

processing <strong>and</strong> is generated when a second attempt (retry) to seize an outgoing trunk fails.<br />

r. Error Type 2817: glare <strong>error</strong>. This <strong>error</strong> is logged only. It is not a hardware failure <strong>and</strong><br />

hence does not start any <strong>test</strong>ing or generate any alarms. This <strong>error</strong> is the result of a<br />

simultaneous seizure of a 2-way trunk from both the near <strong>and</strong> the far ends. Attempt to place<br />

the call again. If the <strong>error</strong> persists, execute the Tie Trunk Seizure Test (#73), <strong>and</strong> follow its<br />

outlined procedures.<br />

s. Error Type 3840: indicates measurements were in the marginal range. Use list<br />

<strong>test</strong>call detail to examine the specific transmission parameters which are out of spec,<br />

<strong>and</strong> investigate the trunk for that kind of noise. If the noise is acceptable, then the ATMS<br />

thresholds administered on page 4 of the trunk group screen should be changed.<br />

Error Type 3841: indicates that <strong>test</strong> calls made by the Automatic Transmission<br />

Measurement System (ATMS) returned measurements in the unacceptable range.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

984 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Long Test<br />

Sequence<br />

NPE Crosstalk Test (#6) X ND<br />

Looparound <strong>and</strong> Conference Test (#33) X ND<br />

Tie Trunk Seizure Test (#73) X X ND<br />

Tie Trunk Dial Test (#747) X X ND<br />

D/ND 1<br />

1 of 2