CAUTION: Synchronization<br />

SYNC (Port Network Synchronization)<br />

! CAUTION:<br />

administration changes should never be done without consulting<br />

the network’s overall synchronization plan. If you suspect that synchronization<br />

administration changes are needed, follow normal escalation procedures.<br />

Synchronization Switches away from<br />

Current Timing Reference<br />

Synchronization changes away from a DS1 reference (primary or secondary) if the current DS1<br />

reference does not provide a valid timing signal. The other DS1 reference is used if one is<br />

administered <strong>and</strong> providing a valid timing signal. Otherwise, the local oscillator of the<br />

Tone-Clock circuit pack in the same port network as the DS1 reference is used. The following<br />

conditions cause a synchronization switch:<br />

● The current DS1 reference is not inserted (list configuration board location<br />

shows no board).<br />

● The current DS1 reference has a loss of signal <strong>error</strong> (DS1-BD <strong>and</strong> UDS1-BD Error Type<br />

1281), a blue alarm <strong>error</strong> (DS1-BD <strong>and</strong> UDS1-BD Error Type 1793), a red alarm <strong>error</strong><br />

(DS1-BD <strong>and</strong> UDS1-BD Error Type 2049), or a hyperactive Angel <strong>error</strong> (DS1-BD <strong>and</strong><br />

UDS1-BD Error Type 1538). A corresponding alarm log entry is not required.<br />

● DS1 <strong>and</strong> UDS1 circuit packs can be administered with slip detection enabled (the Slip<br />

Detection field is y) on the add ds1 or change ds1 administration screens (See<br />

Administering <strong>Avaya</strong> Aura Communication Manager - 555-233-506). When over half of<br />

the DS1 <strong>and</strong> UDS1 circuit packs administered as slip enabled experience slips, <strong>and</strong> the<br />

primary or secondary synchronization reference is the current synchronization reference,<br />

synchronization tries the other administered synchronization reference if the other<br />

administered reference does not have the previous two conditions. Use list<br />

measurements ds1-log to get an historical perspective of DS1 facility operation.<br />

The following conditions cause a change to the other DS1 reference if one exists <strong>and</strong> the other<br />

DS1 reference is more healthy:<br />

● The current DS1 reference has a misframe <strong>error</strong> (DS1-BD Error Type 3329 to 3345 or<br />

UDS1-BD Error Type 3585-3601). A corresponding alarm log entry is not required.<br />

● The current DS1 reference has a slip alarm (DS1-BD <strong>and</strong> UDS1-BD Error Type 3073 to<br />

3160). A corresponding alarm log entry is required.<br />

If the previous conditions are repaired, synchronization changes back to the primary reference.<br />

LEDs on Tone-Clock Circuit Packs<br />

The specific flashing pattern of a TN768, TN780, or TN2182 Tone-Clock circuit pack’s amber<br />

<strong>and</strong> green LEDs indicates the circuit pack’s status. For example, these flashing LED patterns<br />

indicate whether the Tone-Clock circuit pack is:<br />

● Deriving timing from an external source<br />

● Providing the timing signal for its PN<br />