Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 424: BRI Layer 3 Query Test (#629) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1005 ABORT The endpoint’s MIMs <strong>Support</strong>ed? field is administered to “no.”<br />

1. Enter change station extension to change the field only if<br />

the endpoint documentation reflects support for ISDN-BRI<br />

Management <strong>and</strong> Maintenance Procedures.<br />

1113 ABORT The signaling link between the switch <strong>and</strong> the endpoint or adjunct is<br />

down.<br />

1. Enter <strong>test</strong> port location long to clear any <strong>error</strong>s that<br />

prevent establishment of the signaling link.<br />

2. Examine the results of Test #626. If this <strong>test</strong> aborts or fails, follow<br />

the repair procedure for the Signaling Link Status Test (#626).<br />

3. Escalate problem if BRI Layer 3 Query <strong>test</strong> continues to abort.<br />

1139 ABORT The PN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the packet bus.<br />

2. After completing step 1, enter <strong>test</strong> port location long, <strong>and</strong><br />

review the results of the BRI Port Local LAN Looparound Test<br />

(#618) to verify the repair.<br />

1144 ABRT The PPN’s packet bus is out-of-service.<br />

1. Follow the repair procedures for the PPN’s packet bus.<br />

2. After completing step 1, execute <strong>test</strong> port PCSSpp long <strong>and</strong><br />

review the results of the BRI Port Local LAN Loop Around <strong>test</strong><br />

(#618) to verify the repair.<br />

1422 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />