Table 87: DIOD-DS1 Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

2049 (k) 57473<br />

57474<br />

57475<br />

2305 (l) 50944<br />

2562 (m) 16665<br />

2817 (n) 52992<br />

Associated Test Alarm<br />

Level<br />

3840 (o) Port Audit <strong>and</strong><br />

Update (#36)<br />

On/Off<br />

Board<br />

Recommended Action<br />

1. This alarm is raised when the Base Tone Generator field is 4 (Italy) on the System-Parameter<br />

Country screen. This alarm is MINOR unless 75% or more trunks in this trunk group are out of service, then<br />

the alarm is upgraded to a MAJOR alarm.<br />

2. Major alarms may be downgraded to Warning alarms based on the value used in set options.<br />

Notes:<br />

a. Error Type 0: Run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its recommended procedures.<br />

b. Error Type 1<br />

Aux Data 57408: No tip ground is detected on an outgoing call.<br />

Aux Data 57476: Rotary Dial before Wink.<br />

Aux Data 57477: Rotary Dial pulse too early.<br />

Aux Data 57485: Wink too short for a valid signal.<br />

Aux Data 57487: PBX could not get “loop close” signal.<br />

The DS1 Interface circuit pack detected a hardware fault. These <strong>error</strong>s will cause the DS1<br />

CO Trunk Dial Tone <strong>test</strong> (#314) to run <strong>and</strong> are only considered a problem if the Dial Tone<br />

<strong>test</strong> fails (in which case Error Type 1025 will also show up). In this case, the trunk may be<br />

put in the ready-for-service state (shown as “disconnected” by the status comm<strong>and</strong>), which<br />

allows only incoming calls. Run the DS1 CO Trunk Dial Tone Seizure Test (#314) <strong>and</strong><br />

follow the procedures.<br />

c. Error Type 15: software audit <strong>error</strong> that does not indicate any hardware malfunction. Run<br />

short <strong>test</strong> sequence, <strong>and</strong> investigate any <strong>error</strong>s.<br />

d. Error Type 18: the trunk has been busied out <strong>and</strong> is in the out-of-service state. No calls can<br />

be made on this trunk except Facility Access Test Calls. For details, see Facility <strong>test</strong> calls in<br />

Maintenance Procedures for <strong>Avaya</strong> Aura Communication Manager, Media Gateways <strong>and</strong><br />

Servers (03-300432).<br />

334 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

2 of 2