Table 92: DS1 Interface Options administration 2 of 3<br />

Field Description<br />

Idle Code Set the idle code for all facilities on the TN1654 DS1 converter board. This<br />

field can accept any combination of ones (1) <strong>and</strong> zeros (0) with the<br />

exception that the second left-most digit must be set to one (1) at all times.<br />

Appears on the fiber-link screen for TN1654 DS1 converter circuit packs<br />

CRC This field determines if CRC is enabled for every facility on a TN1654 circuit<br />

pack. The field is y if a cyclic redundancy check (CRC) is to be performed<br />

on transmissions that the board receives.<br />

CRC only applies to E1 operation <strong>and</strong> appears on the Fiber-link screen only<br />

for TN1654 DS1 converter circuit packs with a bit rate of 2.048 Mbps.<br />

DS1<br />

Converter-1<br />

<strong>and</strong><br />

DS1<br />

Converter-2<br />

Line<br />

Compensation<br />

The DS1 facility line signal is pre-equalized at the transmitter on the DS1<br />

converter circuit pack so that DS1 line pulses have correct amplitude <strong>and</strong><br />

shape when they reach the Network Interface (see Figure 19: DS1 Facility<br />

Connections). The amount of equalization necessary is determined by the<br />

distance to the Network Interface, <strong>and</strong> also by the type of wiring used to<br />

connect to the Network Interface. If the equalization is not set to the correct<br />

value, potentially high <strong>error</strong> rates (<strong>error</strong>ed seconds) will be observed on the<br />

DS1 facility. Table 93: DS1 Facility Line Signal Equalization Values<br />

explains how equalization values are determined.<br />

Line compensation is applicable only to T1 operation, thus these fields will<br />

not appear on the fiber-link screen if the TN1654 DS1 converter is<br />

administered for a bit rate of 2.048 Mbps.<br />

Line Coding Administer the line coding for the DS1 facility. For the TN574 board <strong>and</strong> the<br />

TN1654 board in T1 mode, the field may be set to ami-zcs or b8zs. If the<br />

TN1654 board is set for E1 operation, the line coding may be set to either<br />

ami-basic or hdb3. The line coding must be the same at each end of the<br />

DS1 converter complex.<br />

360 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />