f. Error Type 515: For the TN802B only, this Error Type indicates that every DSP is OOS (out<br />

of service), <strong>and</strong> a MINOR alarm is raised. The Aux Data field contains the number of DSPs<br />

that are OOS.<br />

g. Error Type 770: DSP overallocation <strong>error</strong>. Since this <strong>error</strong> causes the DSP audit to run, the<br />

condition is cleared <strong>and</strong> no action is necessary. This <strong>error</strong> is logged only. No alarms are<br />

generated.<br />

h. Error Type 1025: The port is OOS (out of service) because of a board-level failure. Check<br />

for <strong>error</strong>s/alarms against the board, in particular ping problems, IP address inconsistency, or<br />

board sanity problems.<br />

1. Verify correct administration.<br />

2. Check cabling <strong>and</strong> customer network before replacing circuit pack.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

Long Test<br />

Sequence<br />

618 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

D/ND 1<br />

DSP Query Test (#1382) X X ND<br />

DSP Port TDM Looparound Test (#1380) X X ND<br />

DSP Port Status Query Test (#1407) X X ND