Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 375: Expansion Interface Local Looparound Test (#240) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time.<br />

2100 Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

2500 Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1 FAIL Loopback on TDM Bus A failed. Loopback on TDM Bus B passed.<br />

2 Loopback on TDM Bus B failed. Loopback on TDM Bus A passed.<br />

3 Loopback on both TDM Buses failed.<br />

12 Loopback on TDM Bus B failed. Loopback on TDM Bus A aborted<br />

because the system could not allocate time slots.<br />

21 Loopback on TDM Bus A failed. Loopback on TDM Bus B aborted<br />

because the system could not allocate time slots.<br />

None The <strong>test</strong> tone was not detected correctly after being looped through the<br />

EI circuit pack.<br />

1. Enter display <strong>error</strong>s <strong>and</strong> check if Error Type 2305 has been<br />

logged against the EI circuit pack in the last 5 minutes. If so, this<br />

<strong>test</strong> could have failed due to the associated slips. First resolve the<br />

2305 <strong>error</strong>, then repeat the <strong>test</strong>.<br />

2. Run the <strong>test</strong>s for the active Tone-Clock on the PN that contains the<br />

indicted EI circuit pack to verify that dial-tone is supplied.<br />

3. If the tone-clock is healthy, repeat the short <strong>test</strong> on the EI board.<br />

4. If this <strong>test</strong> continues to fail, replace the EI circuit pack.<br />

PASS Test tone was correctly detected after internal EI loopback on both TDM<br />

buses.<br />

1. Refer to other EI circuit pack <strong>test</strong>s if the links between this EI circuit<br />

pack <strong>and</strong> the EI or SNI circuit pack on the other end of the fiber is<br />

not functioning correctly.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for repair procedures.<br />

1314 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />