Table 454: Far-End Internal Loopback Test (#797) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Far-End Internal Loopback Test (#797)<br />

FAIL Far-End Internal loopback failed. A problem exists between DS1<br />

converter A <strong>and</strong> DS1 converter B’s internal interface for the DS1 facility<br />

See Figure 109: Far-End Internal Loopback Test Configuration.<br />

1. Enter display <strong>error</strong>s <strong>and</strong> follow the associated repair<br />

procedures for any on-board DS1C-BD (DS1 Converter Circuit<br />

Pack) <strong>error</strong>s on this DS1 converter circuit pack <strong>and</strong> the DS1<br />

converter circuit pack at the other end of the DS1 converter<br />

complex.<br />

2. If the network is used instead of private T1 lines, verify that the DS1<br />

facility <strong>and</strong> the network are using the same Line Coding. For TN574<br />

boards <strong>and</strong> TN1654 boards in T1 mode, also verify that the<br />

Framing Mode used is the same. Enter list fiber-link <strong>and</strong><br />

display fiber-link to check the values for this DS1 facility.<br />

Contact T1 Network Service to check the modes used by the<br />

network. See Line Coding <strong>and</strong> Framing Mode for details on how<br />

these options apply to the TN574 <strong>and</strong> TN1654 DS1 converter<br />

boards.<br />

3. Isolate the problem by running the Near-End External Loopback<br />

<strong>test</strong> (#799) with <strong>test</strong> ds1-facility location<br />

external-loopback, first at this end <strong>and</strong> then at the other end of<br />

the DS1 converter complex. Set up loopbacks at different points as<br />

shown in the description diagram for Test #799, <strong>and</strong> follow repair<br />

procedures described for Near-End External Loopback Test (#799).<br />

4. If the problem could not be found by near-end external loopback<br />

<strong>test</strong>s, the fault should be between the CSU A <strong>and</strong> the CSU B.<br />

Contact T1 Network Service to resolve the problem. Also see the<br />

repair procedures for Error Type 1025 (loss of frame alignment) for<br />

DS1C-BD (DS1 Converter Circuit Pack).<br />

Any PASS Transmission through the path of the loopback is successful. TN1654 DS1<br />

facilities will display the round trip delay time in milliseconds in the Error<br />

Code field. The round trip delay time is defined as the length of time in<br />

milliseconds it takes for the firmware to receive the <strong>test</strong> pattern after it has<br />

been sent.<br />

3 of 3<br />

Issue 5 May 2009 1515