Error log entries <strong>and</strong> recommended actions<br />

Table 231: SN-CONF Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 (a) 0 Any Any Any <strong>test</strong> board location<br />

5000 (b) Any Processor Route Audit (#760) MIN OFF <strong>test</strong> board location l<br />

6000 (c) 1 Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6000 (c) 2 Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6001 (d) Any Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6002 (e) 1 Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6002 (e) 2 Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6003 (f) Any Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6004 (g) Any Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6005 (h) Any Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6005 (h) 1 Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6005 (h) 2 Configuration Audit (#759) MAJ OFF <strong>test</strong> board location<br />

6006 (i) Any Configuration Audit (#759) MIN OFF <strong>test</strong> board location<br />

6007 (j) Any Configuration Audit (#759) MIN OFF <strong>test</strong> board location<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 5000: at least one administered circuit pack in this switch node carrier was not<br />

inserted, or one or more administered circuit packs in this switch node carrier did not<br />

respond to Test #760 with a “board insertion” uplink message.<br />

To resolve this <strong>error</strong>, run the Processor Route Audit Test (#760) using<br />

<strong>test</strong> board location l for an SNC in the same switch node carrier that has this <strong>error</strong>.<br />

844 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers