Table 549: Ring Generator Status Test (#1540)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1035 ABORT The port network is not available.<br />

1. Verify that the port network is not available by using<br />

status port-network<br />

1990 ABORT All inserted power supplies in the carrier are turned off.<br />

Ring Generator Status Test (#1540)<br />

2029 ABORT There is a problem communicating with the environmental maintenance<br />

firmware.<br />

1. Enter <strong>test</strong> maintenance nn to verify communication with the<br />

port network.<br />

2100 ABORT The system could not allocate resources.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

2. If the <strong>test</strong> continues to abort escalate the problem.<br />

2319 ABORT The EPN is out of range.<br />

2500 ABORT An internal operation failed.<br />

1. Repeat the comm<strong>and</strong> at one-minute intervals 1 to 3 times.<br />

11 FAIL The ring generator is active, but overloaded.<br />

2<br />

The ring generator is inactive because of a short.<br />

4<br />

There is an internal fault in the ring generator.<br />

8<br />

The ring generator is off by comm<strong>and</strong>.<br />

16<br />

The ringer on the primary power supply is not active.<br />

32<br />

There is no ringing voltage on the backplane.<br />

1. Run <strong>test</strong> board location<br />

2. If the <strong>test</strong> continues to fail, replace the power supply.<br />

64 FAIL Duplicated power supplies only. Unable to run the ring <strong>test</strong> because the<br />

power supply being <strong>test</strong>ed has its ringer turned off.<br />

PASS The ring voltage was successfully detected.<br />

NO<br />

BOARD<br />

Power supply is administered but not detected.<br />

1. Verify that the power supply is plugged in.<br />

2. If the power supply was already plugged in, replace the power<br />

supply.<br />

Issue 5 May 2009 1707