Table 317: Single-Carrier Cabinet Power Query Test (#79) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Tone Generator Crosstalk Test (#90)<br />

Tone Generator Crosstalk Test (#90)<br />

1 FAIL There is a problem with the environment of the power system.<br />

1. The power supply to any one of the carriers may have been lost.<br />

a. Verify, <strong>and</strong> if necessary restore, AC power at the wall outlet for<br />

each carrier.<br />

b. Rerun the <strong>test</strong>. If the <strong>test</strong> still fails, proceed to step 2.<br />

2. One of the WP-91153 or 676-B power units for one of the carriers<br />

could be defective.<br />

a. If the yellow status LED on a WP-91153 or 676-B power unit is<br />

off, replace the power unit. See Chapter 11: Component<br />

replacement in Maintenance Procedures for <strong>Avaya</strong> Aura<br />

Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432).<br />

b. Rerun the <strong>test</strong>. If the <strong>test</strong> still fails, proceed with Step 3.<br />

3. The PN’s MAINT (Maintenance circuit pack) could be incorrectly<br />

reporting this <strong>error</strong>. Resolve every alarm on these MOs, <strong>and</strong> rerun<br />

the <strong>test</strong>. There are failures that can occur on the PN’s Maintenance<br />

circuit pack that will not be detected but that will cause many, if not<br />

all, environment <strong>test</strong>s to fail. If more than two environment <strong>test</strong>s are<br />

failing, replace the suspect circuit pack, depending on the system<br />

configuration, <strong>and</strong> rerun the <strong>test</strong>.<br />

4. If the <strong>test</strong> still fails, follow normal escalation procedures.<br />

PASS The PN’s Maintenance circuit pack has reported no problem with power.<br />

The Tone Generator Crosstalk Test verifies the ability of the Tone Generator to talk on a specific<br />

time slot. The other idle time slots are checked to make sure the Tone Generator put the tone on<br />

only the specified time slot.<br />

This <strong>test</strong> runs on the following maintenance objects:<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

2 of 2<br />

Issue 5 May 2009 1187