Table 282: Dial Tone Test (#0) 3 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The trunk was seized, but dial tone could not be detected.<br />

CO-TRK:<br />

1. Test every administered outgoing port on the board.<br />

Dial Tone Test (#0)<br />

● Failure of one port indicates a problem toward the CO.<br />

● If every port fails, see note below.<br />

2. Check for TONE-BD <strong>and</strong> TONE-PT <strong>error</strong>s. Clear any <strong>error</strong>s found,<br />

<strong>and</strong> repeat the <strong>test</strong>.<br />

● If the <strong>error</strong> has still not cleared, refer the problem to the CO.<br />

3. If no service problems exist on the port, continue to use the port<br />

until the circuit pack or media module can be replaced as a last<br />

resort. Perform a trunk <strong>test</strong> call to see if the trunk is operable.<br />

Note:<br />

Note: If the dial tone <strong>test</strong> fails for every port on a circuit pack or<br />

media module, a -5 Volt power problem is indicated. To<br />

investigate problems with a power unit, see CARR-POW<br />

(Carrier Power Supply) or RMC-ENV (Power/Fan<br />

Sensors).<br />

DIOD-TRK:<br />

1. Check for TONE-BD <strong>and</strong> TONE-PT <strong>error</strong>s. Clear any <strong>error</strong>s <strong>and</strong><br />

repeat the <strong>test</strong>.<br />

2. If the <strong>error</strong> has still not cleared, refer the problem to the CO.<br />

3 of 4<br />