19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

i. Error Type 1793: DS1 Interface circuit pack or media module is out-of-service. Look in the<br />

Error Log:<br />

If the port is on Look at<br />

TN767 DS1 Board DS1-BD (DS1 Interface Circuit Pack)<br />

TN464 UDS1 Board UDS1-BD (UDS1 Interface Circuit Pack)<br />

DS1 Interface Media Module MG-DS1 (DS1 Interface Media Module)<br />

j. Error Type 2562: Retry Failure <strong>error</strong>. This <strong>error</strong> is logged only. It is not a hardware failure<br />

<strong>and</strong> hence does not start any <strong>test</strong>ing or generate any alarms. This <strong>error</strong> comes from call<br />

processing <strong>and</strong> is generated when a second attempt (retry) to seize an outgoing trunk fails.<br />

k. Error Type 2817: Glare <strong>error</strong>. This <strong>error</strong> is logged only. It is not a hardware failure <strong>and</strong><br />

hence does not start any <strong>test</strong>ing or generate any alarms. This <strong>error</strong> is the result of a<br />

simultaneous seizure of a 2-way trunk from both the near <strong>and</strong> far ends. Attempt to place the<br />

call again. If the <strong>error</strong> persists, execute the Dial Tone Seizure <strong>test</strong> (#314), <strong>and</strong> follow those<br />

procedures.<br />

l. Error Type 3840: Port Audit <strong>and</strong> Update <strong>test</strong> (#36) failed due to an internal system <strong>error</strong>.<br />

Enter status trunk to verify the status of the trunk. If the trunk is out-of-service, then<br />

enter release trunk to put it back into in-service. Retry the <strong>test</strong> comm<strong>and</strong>.<br />

<strong>Dem<strong>and</strong></strong> <strong>test</strong> <strong>descriptions</strong> <strong>and</strong> <strong>error</strong> <strong>codes</strong><br />

Investigate <strong>test</strong>s in the order presented. By clearing <strong>error</strong>s associated with the first <strong>test</strong>, <strong>error</strong>s<br />

generated from other <strong>test</strong>s may also be cleared. Click on the link to see the full description of<br />

the <strong>test</strong>, <strong>error</strong> <strong>codes</strong>, <strong>and</strong> recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

Long Test<br />

Sequence<br />

280 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

D/ND 1<br />

NPE Crosstalk Test (#6) X ND<br />

Conference Circuit Test (#7) X ND<br />

DS1 CO Trunk Dial Tone Seizure Test (#314) X X ND<br />

Port Audit And Update Test (#36) X X ND