ETR-PT (Enhanced Tone Receiver Port)<br />

TN2182 Tone-Clock Circuit Pack (for Non IPSI Connected PNs)<br />

A TN2182 is a combined Tone Generator/Tone Detector board. It provides eight Enhanced Tone<br />

receiver (ETR) ports. Each of these ports provides the functions previously found individually on<br />

DTMR-PTs, GPTD-PTs <strong>and</strong> CLAS-PTs ports. Each port on the TN2182 may be used for any<br />

tone-detection function that was previously done by TN748, TN420, or TN744 Tone Detection<br />

boards.<br />

The TN2182 provides Mu-law or A-law tone-detection capability.<br />

Since the TN2182 also provides Tone-Clock function, only one TN2182 circuit pack may reside<br />

in a PN (or two if your system is duplicated). If more tone-detection resources are needed, the<br />

additional resources must be provided by TN748, TN420, or TN744 circuit packs.<br />

Error log entries <strong>and</strong> recommended actions<br />

Table 106: ETR-PT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

1 (a) any Test #43 Tone Detector Audit/Update<br />

Test<br />

On/Off<br />

Board<br />

Recommended Action<br />

Notes:<br />

a. Error Type 1, 257, 513: There are two possible alarm levels for this Error Type: major alarm<br />

<strong>and</strong> minor alarm. These alarm levels are dependent on the administered thresholds for<br />

TTR, CPTR, <strong>and</strong> CCTR. Each ETR port is capable of operating on any of these.<br />

A major alarm is raised if the total number of ports capable of TTR, CPTR or CCTR<br />

detection currently in service is less than or equal to one-half of the administered TTR,<br />

CPTR, or CCTR threshold number. Otherwise, a minor alarm is raised. The threshold<br />

number of ports for service is administered with change system-parameters<br />

maintenance.<br />

If a major or minor alarm occurs, follow this repair procedure.<br />

1. Use list configuration carrier to get the board type <strong>and</strong> location. If the board<br />

is TN744, then do steps 2–4; if it is TN2182 or TN2312, do steps 5–12.<br />

MAJ<br />

MIN<br />

ON <strong>test</strong> port location r 2<br />

18 busyout port WRN OFF release port location<br />

257 (a) (b) 17666 Test #43 Tone Detector Audit/Update<br />

Test<br />

513 (a) (c) any Test #43 Tone Detector Audit/Update<br />

Test<br />

MAJ<br />

MIN<br />

MAJ<br />

MIN<br />

ON <strong>test</strong> port location r 3<br />

ON <strong>test</strong> port location r 3<br />

Issue 5 May 2009 423