Table 328: Ring Generator Query Test (#118) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Ring Generator Query Test (#118)<br />

FAIL The ringing voltage is below acceptable levels. There are two<br />

procedures: A procedure for a multicarrier cabinet system, <strong>and</strong> a<br />

procedure for a single-carrier cabinet system.<br />

Procedure for a multicarrier cabinet system:<br />

1. If this is a duplicated system, enter status port-network to<br />

determine the active Tone-Clock circuit pack.<br />

2. Enter set tone-clock location to make the st<strong>and</strong>by<br />

Tone-Clock circuit pack active<br />

3. Rerun the <strong>test</strong>.<br />

a. If the <strong>test</strong> passes, the trouble is with the now st<strong>and</strong>by<br />

Tone-Clock circuit pack. See TONE-BD (Tone-Clock Circuit<br />

Pack) for details on replacing the st<strong>and</strong>by Tone-Clock circuit<br />

pack. After the circuit pack is replaced, enter set<br />

tone-clock location to make this Tone-Clock active<br />

again, <strong>and</strong> rerun the <strong>test</strong>.<br />

b. If the <strong>test</strong> fails, resolve CARR-POW (Carrier Power Supply)<br />

alarms first, <strong>and</strong> rerun the <strong>test</strong>. If the <strong>test</strong> still fails:<br />

● Check the fuse on the power distribution unit. Replace the<br />

fuse if it is open, <strong>and</strong> rerun the <strong>test</strong>.<br />

● If the <strong>test</strong> still fails, an analog line circuit pack could be<br />

defective <strong>and</strong> causing the ring generator <strong>and</strong>/or fuse to fail.<br />

Unseat every analog circuit pack in the affected cabinet,<br />

<strong>and</strong> rerun the <strong>test</strong>.<br />

● If the <strong>test</strong> passes, the ring generator is healthy, <strong>and</strong> one of<br />

the analog circuit packs is defective. Replace the analog<br />

circuit packs one at a time, <strong>and</strong> rerun the <strong>test</strong> to determine<br />

which circuit pack is causing the problem. When the<br />

defective analog circuit pack is found, replace it <strong>and</strong> rerun<br />

the <strong>test</strong>.<br />

● If the <strong>test</strong> still fails, proceed with the next step.<br />

2 of 4<br />

Issue 5 May 2009 1211