Table 210: PMS-LINK Error Log Entries 2 of 2<br />

Error Type Aux Data Associated Test Alarm<br />

Level<br />

769 (e) Any<br />

1025 (f) 40–49<br />

1281 (g) 10–19<br />

1537 (h) N0–N9<br />

1793 (i) Any <strong>test</strong> pms-link<br />

2049 (j) Any<br />

2305 (k) 50–59 release pms-link, or<br />

<strong>test</strong> pms-link<br />

2561 (l) Any <strong>test</strong> pms-link<br />

2817 (m) 100–109<br />

200–209<br />

300–309<br />

3073 (n) 70–79<br />

3841 (o) 20–29<br />

1. Minor alarms on this MO may be down graded to Warning alarms based on the value in set<br />

options.<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each <strong>test</strong>’s description, <strong>and</strong> follow its procedures.<br />

b. Error Type 18: the PMS Link has been busied out with busyout pms-link. The link is<br />

torn down. Enter release pms-link to restore the link.<br />

c. Error Type 257: the Link Retry <strong>test</strong> (#215) fails. An <strong>error</strong> was detected when setting up the<br />

link. Refer to the Procedures for Restoring the PMS Link above.<br />

d. Error Type 513: the PMS physical link is down for one of the following reasons:<br />

● Cable to the PMS device is disconnected.<br />

● The PMS device is powered off.<br />

On/Off<br />

Board<br />

Recommended Action<br />

● The data extension to which the PMS device connects has been busied out.<br />

Check the connectivity of wire <strong>and</strong> cable among wall jacket, data module, <strong>and</strong> the PMS<br />

device. Enter status data extension <strong>and</strong> verify that the data extension of the PMS<br />

device is in the in-service/idle state. If the data extension is not available, then see<br />

Procedures for Restoring the PMS Link.<br />

746 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />