Expansion Interface Lightwave Transceiver Looparound Test (#242)<br />

Table 377: Expansion Interface Lightwave Transceiver Looparound Test (#242) 4 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1 FAIL The <strong>test</strong> did not detect the <strong>test</strong> tone through the looparound connection.<br />

The packet portion of this <strong>test</strong> was not run since the circuit portion failed.<br />

1. Test the active Tone-Clock on the PN that contains the defective EI<br />

circuit pack to verify that dial tone is being supplied.<br />

2. If the Tone-Clock is healthy, enter <strong>test</strong> board location long<br />

on the EI circuit pack.<br />

3. If this <strong>test</strong> continues to fail, replace the EI circuit pack or transceiver.<br />

Then enter <strong>test</strong> board location long on the new EI circuit<br />

pack.<br />

2 FAIL The <strong>test</strong> tone was transmitted <strong>and</strong> detected correctly, but the correct data<br />

packet was not detected by the TN1655 Packet Interface circuit pack.<br />

1. Test the TN1655 Packet Interface circuit pack to verify that it is<br />

functioning properly. If any <strong>test</strong>s fail, investigate those <strong>test</strong>s <strong>and</strong><br />

repair the Packet Interface circuit pack.<br />

2. If the Packet Interface circuit pack checks out OK, enter display<br />

<strong>error</strong>s <strong>and</strong> display alarms <strong>and</strong> resolve any SNI-BD <strong>and</strong><br />

FIBER-LK alarms or <strong>error</strong>s (Center Stage Switch only) <strong>and</strong><br />

DS1C-BD alarms or <strong>error</strong>s (if present).<br />

3. Enter <strong>test</strong> board location long on the EI board.<br />

4. If Test #242 continues to fail, replace the EI board. Then enter <strong>test</strong><br />

board location long for the new EI board.<br />

5. If Test #242 continues to fail, replace the lightwave transceiver,<br />

reset the circuit pack <strong>and</strong> enter <strong>test</strong> board location long on<br />

the EI circuit pack.<br />

4 of 5<br />

Issue 5 May 2009 1327