Expansion Interface Local Looparound (#240)<br />

Expansion Interface Local Looparound (#240)<br />

Table 374: Expansion Interface Fiber Out-of-Frame Query Test (#238) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

FAIL The EI circuit pack could not detect the framing signal. Several fail <strong>codes</strong><br />

may be returned depending on which endpoint cot frame up. Error <strong>codes</strong><br />

2326, 2327, <strong>and</strong> 2328 denote Endpoint 1, Endpoint 2, <strong>and</strong> both endpoints,<br />

respectively.<br />

1. Clear any SYNC <strong>and</strong> TDM-CLK <strong>error</strong>s listed in the <strong>error</strong> log.<br />

2. Run <strong>test</strong> board location for each EI board on this fiber link <strong>and</strong><br />

follow the appropriate repair sequence for any failing <strong>test</strong>s.<br />

3. If the EI circuit pack that is failing Test #238 is in the PN, <strong>and</strong> the red<br />

LEDs are ON for a large number of circuit packs, then reseat any<br />

Tone-Clock circuit packs in the PN. See Replacing the IPSI or<br />

Tone-Clock Circuit Pack instructions.<br />

4. Enter display <strong>error</strong>s <strong>and</strong> follow the associated repair<br />

procedures for any SNC-BD (Switch Node Clock Circuit Pack) (if<br />

applicable to this fiber link configuration) or TDM-BUS (TDM Bus)<br />

<strong>error</strong>s.<br />

5. Perform the Fiber link fault isolation procedures described in Chapter<br />

4: General troubleshooting in Maintenance Procedures for <strong>Avaya</strong><br />

Aura Communication Manager, Media Gateways <strong>and</strong> Servers<br />

(03-300432).<br />

6. If the <strong>test</strong> continues to abort, follow normal escalation procedures.<br />

PASS The EI circuit pack(s) have detected the valid framing signal on the fiber.<br />

1. Refer to <strong>error</strong>s from other EI circuit packs, SNI (SNI) <strong>test</strong>s, or DS1<br />

Converter <strong>test</strong>s (if present) if the link is still not functioning.<br />

2 of 2<br />

The EI local looparound <strong>test</strong> is similar to the Lightwave Transceiver Looparound <strong>test</strong> (#242). A<br />

<strong>test</strong> tone is received by the EI being <strong>test</strong>ed, but is not transmitted out to the fiber interface<br />

before being looped back. The loopback is internal to the circuit pack. This <strong>test</strong> does not<br />

interfere with the normal fiber data stream.<br />