Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

● AC-POWER<br />

● CABINET (Cabinet Sensors)<br />

● CARR-POW (Carrier Power Supply)<br />

● DC-POWER (Single-Carrier Cabinet Environment)<br />

● EMG-XFER (Emergency Transfer)<br />

● POWER<br />

Table 331: Emergency Transfer Query Test (#124) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description/Recommendation<br />

1000 ABORT System resources required to run this <strong>test</strong> are not available.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

2000 ABORT Response to the <strong>test</strong> was not received within the time allowed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

2. If the <strong>test</strong> continues to ABORT with Error Code 2000, check for<br />

system powering problems with the PN’s A carrier. Resolve every<br />

AC-POWER <strong>and</strong> CARR-POW (Carrier Power Supply) alarm in a<br />

multicarrier cabinet system or DC-POWER (Single-Carrier Cabinet<br />

Environment) alarm. Repeat the <strong>test</strong>.<br />

3. If the <strong>test</strong> continues to ABORT with a 2000 Error Code, resolve every<br />

MAINT (PN Maintenance Circuit Pack) <strong>error</strong> in a PN. Repeat the <strong>test</strong>.<br />

2029<br />

2100<br />

2319<br />

2500<br />

1<br />

17<br />

18<br />

20<br />

33<br />

65<br />

289<br />

2<br />

24<br />

90<br />

ABORT Internal system <strong>error</strong><br />

1. Retry the comm<strong>and</strong> at 1-minute intervals a maximum of 5 times.<br />

FAIL The Emergency Transfer switch is in the OFF position.<br />

1. Place the switch in the AUTO position.<br />

FAIL The Emergency Transfer switch is in the ON position.<br />

1. Place the switch in the AUTO position.<br />