Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 339: Red Alarm Inquiry Test (#140) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

2000 ABORT Response to the <strong>test</strong> was not received within the allowed time. This may<br />

be due to hyperactivity.<br />

1. Enter display <strong>error</strong>s on the SAT.<br />

2. Check for Error Type 1538 for this DS1 board. If Error Type 1538<br />

appears in the <strong>error</strong> log for this board, see Hyperactive DS1/UDS1<br />

Interface Circuit Pack/Media Module for the repair procedures.<br />

Otherwise, retry the <strong>test</strong> at 1-minute intervals up to 5 times.<br />

2100 ABORT Could not allocate resources for this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />

FAIL The DS1 circuit pack or media module detected a Red Alarm. An<br />

out-of-frame condition occurred. The DS1 circuit pack/media module will<br />

transmit a Yellow Alarm to the remote DS1 endpoint until the Red Alarm is<br />

retired.<br />

1 FAIL The DS1 circuit pack or media module detected a loss of multiframe alarm<br />

(LMA). An out-of-frame condition occurred on the DS1 board. The DS1<br />

board will transmit a remote multiframe alarm (RMA) to the remote DS1<br />

endpoint until the LMA is retired.<br />

1. If the DS1/UDS1 circuit pack or media module connects to a T1<br />

network facility or to another switch, see T1 Network Facility<br />

Procedures<br />

Yellow Alarm Inquiry Test (#141)<br />

2. If the DS1/UDS1 circuit pack or media module connects to a<br />

line-side terminating device such as a PRI terminal adapter, see<br />

Line-side Terminating Device Procedures<br />

PASS No Red alarm is detected on the DS1/UDS1 circuit pack or media module.<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

See NO BOARD for the repair procedures.<br />

The Yellow Alarm Inquiry Test determines whether the remote DS1 endpoint is transmitting a<br />

Yellow alarm. A Yellow Alarm indicates that the remote DS1 endpoint has an out-of-frame<br />

condition.<br />

1248 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />