19.12.2012 Views

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

Demand test descriptions and error codes - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

Table 499: ATM Board Framer Looparound Test (#1260) 4 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2060 ABORT The link on the packet bus being used to perform the <strong>test</strong> has failed.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2. If the <strong>test</strong> continues to abort, enter display <strong>error</strong>s <strong>and</strong> resolve<br />

any PKT-INT (Packet Interface) <strong>error</strong>s.<br />

2100 ABORT Could not allocate the necessary system resources to run this <strong>test</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system <strong>error</strong>.<br />

1. Retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1 FAIL The <strong>test</strong> did not detect the <strong>test</strong> tone through the looparound connection.<br />

Note: The<br />

Note:<br />

packet portion of this <strong>test</strong> was not run since the circuit<br />

portion failed.<br />

1. Test the active Tone-Clock (<strong>test</strong> tone-clock location) in the<br />

PN that contains the defective ATM-EI circuit pack <strong>and</strong> verify that<br />

dial tone is reaching the circuit pack. If not, correct the situation.<br />

2. If the Tone-Clock is healthy, enter <strong>test</strong> board location long.<br />

3. If the <strong>test</strong> continues to fail, replace the ATM-EI or ATM-TRK circuit<br />

pack or transceiver.<br />

4. Test the new ATM circuit pack using <strong>test</strong> board location<br />

long.<br />

2 FAIL The <strong>test</strong> tone was transmitted <strong>and</strong> detected correctly, but the correct data<br />

packet was not detected by the Packet Interface circuit pack.<br />

1. Test the Packet Interface circuit pack to verify that it is functioning<br />

properly. If any <strong>test</strong>s fail, see PKT-INT (Packet Interface) for repair<br />

procedures.<br />

2. If the Packet Interface circuit pack is OK, resolve any DS1C-BD<br />

(DS1 Converter Circuit Pack) alarms or <strong>error</strong>s, if applicable.<br />

3. Enter <strong>test</strong> board location long.<br />

4. If this <strong>test</strong> continues to fail, replace the ATM board.<br />

5. Test the new ATM circuit pack with <strong>test</strong> board location long.<br />

1616 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

4 of 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!