VC-BD (Voice Conditioner Circuit Pack)<br />

Notes:<br />

a. Error Type 0: run the short <strong>test</strong> sequence first. If every <strong>test</strong> passes, run the long <strong>test</strong><br />

sequence. Refer to each appropriate <strong>test</strong>’s description, <strong>and</strong> follow its recommended<br />

procedures.<br />

b. Error Type 1: the circuit pack stopped functioning or it was removed from the system. This<br />

alarm is logged approximately 11 minutes after the circuit pack is removed <strong>and</strong>/or the SAKI<br />

Sanity <strong>test</strong> (#53) fails.<br />

To resolve this <strong>error</strong>, insert a circuit pack in the same slot as the <strong>error</strong> indicates, if the<br />

circuit pack is not already in the system. Or, if the circuit pack is in the system <strong>and</strong> the red<br />

LED is on, then follow instructions for Red alarms.<br />

CAUTION: If<br />

! CAUTION:<br />

the TN788 Voice Conditioner circuit pack (VC-BD) is not Vintage 2 or later, it<br />

must be replaced.<br />

c. Error Type 18: this circuit pack is busied out by busyout board location.<br />

d. Error Type 257: transient communication problems exist between the switch <strong>and</strong> this circuit<br />

pack. Execute <strong>test</strong> board location <strong>and</strong> see the repair procedures for the Control Chel<br />

Looparound Test (#52).<br />

e. Error Type 513: the circuit pack detected an on-board hardware failure. The reported Aux<br />

Data values correspond to the following detected <strong>error</strong>s:<br />

Error Description<br />

4352 External RAM <strong>error</strong><br />

4353 Internal RAM <strong>error</strong><br />

4355 ROM Checksum <strong>error</strong><br />

4357 Instruction set <strong>error</strong><br />

Reset the circuit pack by executing busyout board location, reset board<br />

location, <strong>and</strong> release board location. When it is reset, the circuit pack executes<br />

a set of <strong>test</strong>s to detect the presence of any of the above faults. The detection of one these<br />

<strong>error</strong>s during initialization causes the circuit pack to lock-up <strong>and</strong> appear insane to the<br />

system. See the repair procedures in footnote (a) for Error Type 1.<br />

f. Error Type 769: the circuit pack detects a program logic <strong>error</strong>. While no action is required,<br />

this <strong>error</strong> may lead to <strong>error</strong>s of other types being reported against this circuit pack.<br />

g. Error Type 1025: the circuit pack cot update NPE memory <strong>and</strong> read it back. This Error Type<br />

can be ignored, but it may lead to other Error Types being reported against this circuit pack.<br />

h. Error Type 1281: a critical hardware failure has been detected on the circuit pack. Use<br />

busyout board location, reset board location, followed by release board<br />

location. If Test #53 passes, the on-board circuitry is healthy. Use <strong>test</strong> board<br />

location long clear to retire the alarm. If Test #53 fails, replace the circuit pack.<br />

Issue 5 May 2009 1053