Table 334: OLS/Power Unit Query Test (#127) 2 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

OLS/Power Unit Query Test (#127)<br />

FAIL AC-POWERED SYSTEMS<br />

There is a problem with one or both OLSs on the <strong>test</strong>ed carrier.<br />

1. For each OLS that has every status LED OFF, check the AC input to<br />

the OLS at the OLS outlet. If there is no AC, then check the<br />

appropriate fuses for the affected OLS. Replace open fuses. If the<br />

fuses open again or AC does not show up at the OLS outlet, then<br />

there is probably a power wiring problem in the cabinet.<br />

2. At this point, AC should be present at the OLS outlet. Enter<br />

recycle carrier UUC, where UUC is the appropriate cabinet<br />

<strong>and</strong> carrier, in an attempt to bring back the OLSs for this carrier. If<br />

the <strong>test</strong> passes, the trouble is cleared. If the <strong>test</strong> does not pass, one<br />

OLS or both in the <strong>test</strong>ed carrier is defective. If only one OLS is<br />

defective, then the status LEDs on the healthy OLS will light green<br />

for a moment. When the recycle <strong>test</strong> determines that both OLSs are<br />

defective, the software will turn off power to both the good <strong>and</strong><br />

defective OLSs. This will cause the status LED(s) on the good OLS<br />

to light red.<br />

3. Unplug both OLSs, <strong>and</strong> wait approximately 1-minute to allow the<br />

OLSs to cool down. Plug in the OLSs. If either OLS is operating<br />

properly (the status LEDs show green), replace the defective<br />

OLS(s). See CARR-POW (Carrier Power Supply)<br />