Maintenance <strong>Dem<strong>and</strong></strong> Tests<br />

This <strong>test</strong> runs on EXP-INTF (Expansion Interface Circuit Pack).<br />

Table 375: Expansion Interface Local Looparound Test (#240) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1 ABORT Could not allocate time slot on TDM Bus A. Loopback passed on TDM<br />

Bus B.<br />

1. If there is no reason to doubt that the EI circuit pack can transfer<br />

data to or from a TDM Bus, then since the <strong>test</strong> passed on one bus,<br />

assume that the <strong>test</strong> passes on the other bus.<br />

2. If this <strong>test</strong> continues to abort with the same <strong>error</strong>, rerun <strong>test</strong> at<br />

1-minute intervals up to 3 times.<br />

3. If the <strong>test</strong> still does not pass on the other TDM Bus, follow the<br />

procedure for ABORT Error Code 3.<br />

2 ABORT Could not allocate time slot on TDM Bus B. Loopback passed on TDM<br />

Bus A.<br />

1. If there is no reason to doubt that the EI circuit pack can transfer<br />

data to or from a TDM Bus, then since the <strong>test</strong> passed on one bus,<br />

assume that the <strong>test</strong> passes on the other bus.<br />

2. If this <strong>test</strong> continues to abort with the same <strong>error</strong>, rerun <strong>test</strong> at<br />

1-minute intervals up to 3 times.<br />

3. If the <strong>test</strong> still does not pass on the other TDM Bus, follow the<br />

procedure for ABORT Error Code 3.<br />

3 ABORT The system could not allocate time slots for the <strong>test</strong> on either TDM Bus.<br />

The system may be under heavy traffic conditions or it may have time<br />

slots out of service due to TDM-BUS <strong>error</strong>s.<br />

1. If the system has no TDM-BUS <strong>error</strong>s <strong>and</strong> is not h<strong>and</strong>ling heavy<br />

traffic, retry the comm<strong>and</strong> at 1-minute intervals up to 3 times.<br />

1003 ABORT The system could not allocate a tone receiver for the <strong>test</strong>. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see<br />

information regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) <strong>error</strong>s.<br />

3. Resolve any TONE-PT (Tone Generator) <strong>error</strong>s.<br />

4. Retry the comm<strong>and</strong> at 1-minute intervals up to 5 times.<br />