Figure 53: PRI Endpoint Port Interactions<br />

Terminal<br />

Adapter<br />

ISDN-LNK<br />

PE-BCHL<br />

PE-BCHL<br />

Signaling<br />

(Port 24)<br />

Data<br />

(Port 23)<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

.<br />

Data<br />

(Port 1)<br />

PRI Endpoint Port Service States<br />

UDS1<br />

Interface<br />

Circuit<br />

Pack<br />

(TN464C)<br />

MSSNET<br />

Circuit<br />

Pack<br />

(UN332)<br />

The status pri-endpoint extension comm<strong>and</strong> displays the following possible service<br />

states for PRI endpoint ports. The table that follows gives recommended procedures for each<br />

state. The figure following that shows typical progressions from one service state to another.<br />

Refer also to Troubleshooting ISDN-PRI endpoints (wideb<strong>and</strong>) in Maintenance Procedures for<br />

<strong>Avaya</strong> Aura Communication Manager, Media Gateways <strong>and</strong> Servers (03-300432) for a<br />

layered approach to addressing PRI endpoint problems.<br />

● In-Service (INS)<br />

The B-Channel is in its normal operating state.<br />

● Out-of-Service/Far-End (OOS/FE)<br />

A B-Channel is initialized to this state when first administered. The switch then sends<br />

messages to the far-end terminal adapter to negotiate the B channel into service. If the<br />

far-end terminal adapter does not respond to the messages within a certain time period,<br />

the port remains out of service, <strong>and</strong> maintenance will periodically resend the messages.<br />

The port is unusable for incoming <strong>and</strong> outgoing calls, although other ports in the PRI<br />

endpoint can still be used.<br />

710 Maintenance Alarms for Communication Manager, Media Gateways <strong>and</strong> Servers<br />

Packet<br />

Bus<br />

TDM<br />

Bus<br />

PKTINT<br />

Circuit<br />

Pack<br />

(TN1655)<br />

Processor<br />

(UN331)